  • Technology: olid-State LiFePO₄ High-Power Energy Cabinet
  • Power rating: DC204.8-512V, 50h and 100Ah
  • Phase: 3/3 Phase (DC204.8-512V)
  • Warranty: 5 Year Full Warranty
  • Description: A solid-state LiFePO₄ high-voltage UPS battery cabinet that combines 4C fast recharge, 6C high-power discharge, and a 3-level BMS for safer, smarter energy storage in mission-critical rooms and industrial environments. It is delivered as an integrated cabinet solution and can be specified as Li 204.8V/307.2V/409.6V/512.0V 108Ah with scalable energy expansion by paralleling cabinets.
  • Online ordering

Vekloud Solid-State LiFePO₄ High-Power Energy Cabinet (UPS Battery System)

  • Chemistry / safety: Solid-state LiFePO₄ designed for extreme safety (no swelling, no smoke, no fire, no explosion under severe conditions).

  • Fast recharge: 4C charging — can recover to full capacity in as fast as ~15 minutes after discharge (application dependent).

  • High power output: 6C discharge — supports high inrush / impact loads and large transient currents.

  • Long lifetime: 15-year design life and ~4000 cycles (capacity retention >80% after 4000 cycles under typical test conditions).

  • Wide temperature capability: Charging 0 to +55°C; discharge typically down to -20°C (system dependent).

  • Low footprint / weight advantage: For the same usable energy, footprint and floor loading demand can be about one-third of traditional lead-acid solutions.

  • Integrated delivery: Battery packs + high-voltage box + cabinet + monitoring are integrated; reduces on-site installation workload by 80%+.

  • Smart monitoring & protection: 3-level BMS (cell/module/system) with real-time monitoring, active balancing, multi-layer protections, SOC/SOH tracking, alarms & event logs.

  • HV control unit: Up to 1000 V / 500 A, automatic fault isolation; supports solutions with neutral (where required).

  • Communications: RS485, TCP/IP, dry contacts for UPS/DCIM/BMS integration.

  • Monitoring platforms: Local display + PC + mobile platform; SOC accuracy typically <5%.

  • Scalability: Supports paralleling up to 20 cabinets (energy expansion).

  • Self-discharge: Typically ≤3% per month (at moderate temperatures).

  • Cooling / wiring: Forced-air cooling; supports top or bottom cable entry.

Available configurations (use “Li + actual V/Ah” as the model name)

All options use 108Ah battery packs; voltage increases with series count:

  • Li 204.8V 108Ah22 kWh, 4 packs (series)

  • Li 307.2V 108Ah33 kWh, 6 packs (series)

  • Li 409.6V 108Ah44 kWh, 8 packs (series)

  • Li 512.0V 108Ah55 kWh, 10 packs (series)

UPS sizing principles (quick rules)

  • Ensure the UPS DC voltage window matches the battery system DC window.

  • Energy sizing: (UPS rated capacity × backup hours) ≈ (Battery nominal energy × quantity).

  • Power sizing guideline: UPS rated power should not exceed ~4× the battery system total power capability (to keep high-rate operation within safe margins).