Hello! Welcome to visit the official website of XX Co., Ltd.!
PRODUCTS

Online UPS - 3/3 Phase

Vertiv Liebert Hipulse-U

  • Technology: Online (double conversion) industrial UPS
  • Power rating: 30-500 kVA Models Available
  • Phase: 3/3 Phase (380/400/415V)
  • Warranty: 2 Year Full Warranty
  • Description: Liebert Hipulse-U is a fully digital, online double-conversion UPS (30–500 kVA) built for critical business and industrial applications, offering wide input tolerance, strong overload capability, and excellent compatibility with non-linear and unbalanced loads. With built-in maintenance bypass, front-service access, flexible parallel/dual-bus architectures, and Modbus/SNMP monitoring, it is engineered for high availability and easy lifecycle management.
  • Online ordering

Vertiv Liebert Hipulse-U (30–500 kVA) 

  • Topology / Control: Online double-conversion UPS with an IGBT-based inverter, fully digital architecture with twin DSP control for stable, high-quality output.

  • Power capability: Rated at 0.9 output power factor to deliver more usable active power for real loads.

  • Wide input tolerance: Input voltage range 323–478 VAC; input frequency range 45–65 Hz for better operation on unstable grids and generator supplies.

  • High load compatibility: Designed to handle high crest factor loads, 100% non-linear loads, and 100% unbalanced loads.

  • Overload strength: UPS overload capability: 110% for 60 minutes, 125% for 10 minutes, 150% for 1 minute; static bypass designed for higher overload handling.

  • Power quality: Voltage regulation ±1% (steady state), ±5% (transient); fast transient recovery (typical ~20 ms range); low output distortion (<1% linear, <5% at 100% non-linear).

  • Maintenance & serviceability: Built-in maintenance bypass and front access for spare replacement and preventive maintenance; compact footprint.

  • System architecture options: Supports parallel up to 6 units for scalability/redundancy; supports hot standby and dual-bus architecture (with load transfer/synchronization solutions).

  • Battery investment protection: Automatic battery testing, adjustable end-of-discharge settings, selectable boost charging duration, deep-discharge protection, and optional temperature-compensated charging.

  • Protection & resilience: Short-circuit-proof inverter, integrated back-feed dry contacts, optional lightning protection, and multiple auxiliary power supplies for redundancy on larger frames.

  • Monitoring & communications: Industrial protocols Modbus/Jbus and network monitoring via SNMP, plus standard dry contacts for alarms and control.